Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing

August 2020
Vol-6, Issue-4
Paper ID: 12481
ISSN: 2395-4396
Downloads: 0

Abstract & Details

Research Area
Structural Engineering
Keywords
Keywords-Condition positioning Strengthening Retrofitting Non-dangerous Seismic reaction Water tank.
Abstract
There has been a combined attempt to address the seismic performance of existing structures in India after an earthquake in Bhuj, Gujarat, in 2001. Seismic analysis and seismic retrofit for the existing tanks have become a remarkable problem to be worked since corrosion is a cosmopolitan and natural phenomenon. It is important to know the exact reason for suffering and type of distress. To succeed such problems, a proper technique of restoration and recovery with detailed plans and methodology is required. This research is targeted at evolving systematic investigation metrology for condition position method based on the analytical hierarchy process (AHP) and strengthening by various retrofitting strategies. For that case study, an existing raised water tank is considered, which was designed according to state of the art over 40 years ago as per old Indian Standard (IS) code. The position assessment of the raised service tank was carried out using different non-destructive tests (NDTs). DER, i.e., degree (D), extent (E) and relevancy (R) rating technique was employed to find out the condition index of the elevated service tank (ESR). After finding the condition ranking of the existing structure, an analysis was carried out using SAP 2000 to find the present-day seismic requirements using IS codes. After knowing the seismic demand of the water tank, various retrofitting methods were adopted for improving the drift capacity and flexural capacity of the structure. The results were finally used to discourse some of the critical problems of the seismic response of the retrofitted structure in terms of a time period, mode shapes, base shear, displacement, acceleration, and velocity. From the case study result of seismic retrofit for the existing raised water tank, it is confirmed that a relatively simple seismic retrofit method is effective to keep the tank functional after an earthquake.

Author Information

# Name Institute / Affiliation
1 Balraj Patel Sri Satya Sai University of Technology and Medical Sciences, Pachama, Sehore, M.P.
2 Dr. Ajay Swarup Sri Satya Sai University of Technology and Medical Sciences, Pachama, Sehore, M.P.

How to Cite

Use the following formats to cite this article in your research.

APA Style
Patel, Balraj & Swarup, Dr. Ajay (2020). Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing. International Journal of Advance Research and Innovative Ideas In Education, 6(4), 1362-1368.
MLA Style
Patel, Balraj, and Dr. Ajay Swarup. "Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing." International Journal of Advance Research and Innovative Ideas In Education, vol. 6, no. 4, 2020, pp. 1362-1368.
IEEE Style
Balraj Patel and Dr. Ajay Swarup, "Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing," International Journal of Advance Research and Innovative Ideas In Education, vol. 6, no. 4, pp. 1362-1368, 2020.
Vancouver Style
Patel Balraj, Swarup Dr. Ajay. Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing. International Journal of Advance Research and Innovative Ideas In Education. 2020;6(4):1362-1368.
Harvard Style
Patel, Balraj & Swarup, Dr. Ajay (2020) 'Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing', International Journal of Advance Research and Innovative Ideas In Education, 6(4), pp. 1362-1368.
Chicago Style
Patel, Balraj and Dr. Ajay Swarup. "Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing." International Journal of Advance Research and Innovative Ideas In Education 6, no. 4 (2020): 1362-1368.
Turabian Style
Patel, Balraj and Dr. Ajay Swarup. "Seismic Performance of Existing Water Tank after Condition Position Using Non-Destructive Testing." International Journal of Advance Research and Innovative Ideas In Education 6, no. 4 (2020): 1362-1368.

Export Citation

Related Research

ENERGY ANALYSIS OF RESIDENTIAL BUILDING USING REVIT
Deepti et al. 2026 Civil Engineering
PDF Unavailable
Applications Artificial Intelligence and Machine Learning in Civil Engineering Domain
Abdus Salam Bakhtiyar Ahmed Dafedar et al. 2026 Civil Engineering
PDF Unavailable
Circular Economy in Civil Engineering
SHITALKUMAR S.DESHMUKH et al. 2026 CIVIL ENGINEERING
PDF Unavailable
kicthen organic waste as a material for vermiculture and a source of nutrients for plants
SANTOSH TAMMANNA BASARAGI et al. 2026 Civil Engineering
PDF Unavailable
STUDY ON SEISMIC ANALYSIS OF EARTH DAMS AND EMBANKMENT
Mr. Rahul Paikrao et al. 2025 Civil Engineering
PDF Unavailable