Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India
Abstract & Details
Research Area
Mechanical Engineering
Keywords
PDEC
Evaporative cooling
Energy Efficient
CFD Analysis
Abstract
The climate in Bangalore is characterized by low relative humidity and very high summer ambient temperatures. Space cooling is therefore required to achieve internal thermal comfort. Air-conditioning is the typical cooling solution, and accounts for about 65% of energy use in buildings in this region. This is a notable source of greenhouse gas emissions and coupled with their high-energy demand, alternative means of achieving space cooling would prove invaluable. This paper investigated the applicability of Passive Downdraught Evaporative Cooling (PDEC) in office buildings in this region by using a proposed PDEC system for a Incubation Center as a research vehicle. “Downdraught cooling is an energy efficient, and cost effective alternative to conventional air-conditioning for new and existing buildings” [2]. It is a well-tested system and the climatic conditions of Bangalore favor its application. This study was carried out in three phases; the first phase involved reducing the building cooling loads by appropriate solar control and improving the building envelope; the second phase was an evaluation and optimization of the proposed PDEC system; the third phase involved future-proofing the building by evaluating the performance of the system in the year 2100 using interpolated weather data. Internal comfort conditions were determined based on the adaptive comfort principle and the efficacy of the system was assessed by the percentage of resultant hourly internal temperatures achieved within the target comfort range when the PDEC system was in operation. The CFD analysis was done using FLUENT and the results showed the proposed PDEC system fulfilled the cooling requirements for more than 75% of the required periods (both for present-day and future climatic conditions). The study therefore lends credence to the applicability of PDEC as a viable cooling solution for office buildings in Bangalore and other regions with similar climatic conditions.
License
This work is licensed under a Creative
Commons
Attribution-ShareAlike 4.0 International License.
Author Information
| # | Name | Institute / Affiliation |
|---|---|---|
| 1 | Janakkumar B Paanchal | LDRP-ITR, Gandhinagar, India |
| 2 | Dr. Nirvesh Mehta | LDRP-ITR, Gandhinagar, India |
How to Cite
Use the following formats to cite this article in your research.
APA Style
Paanchal, Janakkumar B & Mehta, Dr. Nirvesh (2017). Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India. International Journal of Advance Research and Innovative Ideas In Education, 3(2), 1662-1674.
MLA Style
Paanchal, Janakkumar B, and Dr. Nirvesh Mehta. "Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India." International Journal of Advance Research and Innovative Ideas In Education, vol. 3, no. 2, 2017, pp. 1662-1674.
IEEE Style
Janakkumar B Paanchal and Dr. Nirvesh Mehta, "Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India," International Journal of Advance Research and Innovative Ideas In Education, vol. 3, no. 2, pp. 1662-1674, 2017.
Vancouver Style
Paanchal Janakkumar B, Mehta Dr. Nirvesh. Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India. International Journal of Advance Research and Innovative Ideas In Education. 2017;3(2):1662-1674.
Harvard Style
Paanchal, Janakkumar B & Mehta, Dr. Nirvesh (2017) 'Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India', International Journal of Advance Research and Innovative Ideas In Education, 3(2), pp. 1662-1674.
Chicago Style
Paanchal, Janakkumar B and Dr. Nirvesh Mehta. "Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India." International Journal of Advance Research and Innovative Ideas In Education 3, no. 2 (2017): 1662-1674.
Turabian Style
Paanchal, Janakkumar B and Dr. Nirvesh Mehta. "Passive Down Draft Evaporative Cooling: The Applicability for Office space cooling in Banglore,India." International Journal of Advance Research and Innovative Ideas In Education 3, no. 2 (2017): 1662-1674.
Related Research
Designing And Manufacturing Of Mecanum Wheel
PDF Unavailable
Experimental, Design and Development of different punch and die for head light reflectors
PDF Unavailable
Experimental Analysis of Aluminium Hybrid Material using Analytical and Experimental Method
PDF Unavailable
Effect of Slight Pitch Difference on the Fatigue Life of Bolt
PDF Unavailable