NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE
Abstract & Details
Research Area
THERMAL ENGINEERING
Keywords
Reynolds number
Heat transfer
Pressure drop
Duct
Relative gap position
Abstract
In this thesis, results of CFD analysis on heat transfer and friction in rectangular ducts with broken double arc shape rib with staggered rib roughness has been presented. The rib roughness has relative roughness pitch of 10, arc angle of 30° and relative roughness height of 0.043. The relative gap position was varied from 0.30 to 0.60. The effects of relative gap position on Nusselt number, friction factor and thermo-hydraulic performance parameter have been discussed and results compared with smooth duct under similar conditions. The rough ribs were efficient enough to transfer the desired heat, but they are not economical and are very complex in design and construction. Whereas, roughness gives more area of contact. So, there is enough time to transfer the heat from the ribs to the passing air which touches the ribs and the heat transfer takes place efficiently. Thus, the broken double arc shape rib with staggered rib with different relative gap position, when compared with the smooth plate, it was concluded that the related Nusselt Number and friction factor for broken double arc shape rib with staggered rib with different relative gap position was more efficient. The smooth plate could not transfer the desired heat due to absence of friction; so, they are not preferred practically. One of the most important techniques used are passive heat transfer technique. These techniques when adopted in heat transfer surfaces proved that the overall thermal performance improved significantly. Rib roughness on the underside of the top wall of a duct has been found to substantially enhance the heat transfer coefficient. Surface roughness disturbs the laminar sub-layer in the turbulent flow and promotes local wall turbulence that, in turn, increases the heat transfer from the surfaces. The augmentation in heat transfer accompanies a higher pressure drop penalty of the fluid flow. In this work the maximum value is found to be relative gap position 0.50 at a Reynolds number of 16000.
License
This work is licensed under a Creative
Commons
Attribution-ShareAlike 4.0 International License.
Author Information
| # | Name | Institute / Affiliation |
|---|---|---|
| 1 | DEVI PRASAD ASOLE | Scope College of Engineering, Bhopal |
| 2 | SANDEEP KUMAR SHAH | Scope College of Engineering, Bhopal |
How to Cite
Use the following formats to cite this article in your research.
APA Style
ASOLE, DEVI PRASAD & SHAH, SANDEEP KUMAR (2020). NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE. International Journal of Advance Research and Innovative Ideas In Education, 6(1), 931-938.
MLA Style
ASOLE, DEVI PRASAD, and SANDEEP KUMAR SHAH. "NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE." International Journal of Advance Research and Innovative Ideas In Education, vol. 6, no. 1, 2020, pp. 931-938.
IEEE Style
DEVI PRASAD ASOLE and SANDEEP KUMAR SHAH, "NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE," International Journal of Advance Research and Innovative Ideas In Education, vol. 6, no. 1, pp. 931-938, 2020.
Vancouver Style
ASOLE DEVI PRASAD, SHAH SANDEEP KUMAR. NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE. International Journal of Advance Research and Innovative Ideas In Education. 2020;6(1):931-938.
Harvard Style
ASOLE, DEVI PRASAD & SHAH, SANDEEP KUMAR (2020) 'NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE', International Journal of Advance Research and Innovative Ideas In Education, 6(1), pp. 931-938.
Chicago Style
ASOLE, DEVI PRASAD and SANDEEP KUMAR SHAH. "NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE." International Journal of Advance Research and Innovative Ideas In Education 6, no. 1 (2020): 931-938.
Turabian Style
ASOLE, DEVI PRASAD and SANDEEP KUMAR SHAH. "NUMERICAL INVESTIGATION OF SOLAR AIR HEATER DUCT USING BROKEN DOUBLE ARC SHAPED RIBS COMBINED WITH STAGGERED RIB PIECE." International Journal of Advance Research and Innovative Ideas In Education 6, no. 1 (2020): 931-938.
Related Research
Designing And Manufacturing Of Mecanum Wheel
PDF Unavailable
Experimental, Design and Development of different punch and die for head light reflectors
PDF Unavailable
Experimental Analysis of Aluminium Hybrid Material using Analytical and Experimental Method
PDF Unavailable
Effect of Slight Pitch Difference on the Fatigue Life of Bolt
PDF Unavailable